Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 59
Quiet Zone Settings
ZZ
Start/End
Program
Menu
-[[-
YN
No margin
check
-ZO-
YO
Margin
check 1/7
normal
-ZP-
YP
Margin
check 2/7
normal
-ZQ-
YQ
Margin
check 3/7
normal
-ZR-
YR
Margin
check 4/7
normal
-ZS-
YS
Margin
check 5/7
normal
-ZE-
YT
Margin
check 6/7
normal
-ZU-
YU
Margin
check
normal
-ZV-
%
With these settings, the reader can decode bar codes that have smaller start and/or end margins than specified for the
symbology. These settings may increase the possibility of partial and ghost reads, hence do not use smaller margin
checks than necessary. Replace any bar code labels with ones that have the correct start and end margins if possible.