Opticon LH2 Manual do Utilizador Página 92

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 102
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 91
Advance Settings
92
Prex \ Sufx
93
Command Name:
VGA & SXGA Mode
Usage:
Sets the imager optical resolution.
Description:
User’s may optimize the LH2’s mega pixel (SXGA) imager (1280 x
1024) to a VGA (640 x 480). This feature is used to decrease the
pixel sampling area, which will greatly increase processing speed.
This is an advanced feature used for the rapid decoding of 1D/linear
barcodes and larger size 2D barcodes. Opticon recommends testing
this feature, as it may not work with certain high density codes.
Default:
Optical resolution is set to 1280 x 1024
Programming Code: Serial Command:
SXGA Mode - 1280 x 1024 (Default) P%e20<┘
P%640<┘
Options:
Programming Code: Serial Command:
VGA Mode - 640 x 480 P%e21<┘
P%640<┘
Vista de página 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 101 102

Comentários a estes Manuais

Sem comentários